S46M5/9 High-current Coupling/Decoupling Network
Features
The “M5” configuration
offers five substantial conductors capable of handling 50ampere circuits such
as 3-phase, neutral, and earth. Special anti-resonance elements (See “Reducing
errors due to resonances in Radiated and Conducted EMC testing” by R C
Marshall, Paper 4F1, Zurich EMC Symposium, Feb. 18th-20th, 2003) allow the use
of these conductors in M2, M3, and M4 mode without loss of accuracy, and they
may also be linked in parallel pairs for two-wire 100 amp circuits.
In the “M9” configuration one of the above five is split into
5 lower-current conductors for the control and sensing circuits that form part
of high-current dc power supplies, for motor drives, or for energising the
voltage measuring circuits of electricity meters.
This configuration also
covers M6, M7 and M8 modes.
The
network may be used for decoupling other cables to the EUT, and will support
emission testing according to EN55022:1998.
S46M5/9 VCDN
Specification
Injection/receiver circuit:
EUT rf common-mode impedance: 150W +- 20W from 0.15 to 26MHz.
150W + 60 - 45W from 26 to 80MHz.
.
Rf input/output: BNC socket. Maximum
continuous input power 3 watts.
For E46xx
only: VSWR < 2.5:1 referred to 50W.
User
circuit:
This network may be configured as any of
the networks for power cables described in EN61000-4-6 and for larger numbers
of cores. As required in the standard
the basic injection impedance of 150W in series with >30nF is applied by
proportionately higher-impedance injection components connected to each
core. Physically the CDN carries 4
major circuits of 4.65mm² cross-section, together with 5 minor circuits of
0.6mm² cross-section. The latter may be used in parallel as a ground wire for
application as M1 to M5 inclusive, and used separately for M6 to M9.
Connectors: EUT and AE cables are connected to screw
terminal blocks that can
accommodate 0.5 to 10mm²
flexible, stranded, or solid conductors.
Max volts: 440
Vac.
Max. current per core: At 30°C ambient. Halve these figures if the fan is not used.
M5, M4: 50amps on 3 phase and neutral or 4
wires carrying dc.
M3: 100amps
on 2 wires and 30amps on the third.
Parallel connecting cables should be used above 50amps.
M2: 100amps
on 2 wires. Parallel connecting cables
above 50amps.
M6-M9: The
above current ratings apply to circuits 1 to 4.
Circuits 5 to 9 are rated at
6amps each.
Max. unbalanced current per cable and for M1 operation: 100mA peak or dc.
AE Filter capacitance: 22nF on each of the major
circuits. 4n7 on each minor circuit.
All capacitors are safety rated.
Longitudinal conversion loss: typically > 40dB.
Cooling Fan: 12Vdc 1.3watts.
Dimensions
(including projections): 280 x 180 x 105mm. Weight 1.6 Kilograms.
Accessories
included: AC/DC Adaptor for fan supply
(UK 13amp plug-mounted unless otherwise requested).
Comprehensive
manual.
Accessories
recommended: Calibration jig pair 46MZZ
is essential.
46MZC Interface Adaptor between VCDN EUT interface and type N
connector available for formal checking of CDN impedance. Ground plane 46GP and extension 46XP available. UKAS Certification available.
These items are components for use only in an appropriate laboratory environment and by suitably qualified and trained staff.
In the search for improved quality this specification is subject to change. Patents applied for. © and Design rights reserved Richard Marshall Limited 2004